home *** CD-ROM | disk | FTP | other *** search
/ Professional Soft Collection 1.02 / Professional Soft Collection 1.02.iso / winfwg.311 / setup.txt < prev    next >
Text File  |  1993-10-20  |  50KB  |  1,147 lines

  1. MS-DOS is a registered trademark and Windows is a trademark of
  2.         Microsoft Corporation. 
  3.  
  4. AT&T is a registered trademark of American Telephone and Telegraph Company.
  5. RAMpage! is a registered trademark of AST Research, Inc.
  6. SideKick is a registered trademark of Borland International, Inc.
  7. PC Tools and PC Tools Deluxe are trademarks of Central Point Software, Inc.
  8. COMPAQ is a registered trademark of Compaq Computer Corporation.
  9. HP is a registered trademark of Hewlett-Packard Company.
  10. IBM and PS/2 are registered trademarks of International Business Machines
  11.         Corporation.
  12. Intel is a registered trademark, and Inboard and LANSight are trademarks,
  13.         of Intel Corporation.
  14. Logitech  is a trademark of Logitech, Inc.
  15. NEC is a registered trademark of NEC Corporation.
  16. Exos, NetWare, and Novell are registered trademarks of Novell, Inc.
  17. Norton Utilities is a registered trademark of Peter Norton Computing,
  18.         Incorporated.
  19. 386MAX is a registered trademark of Qualitas, Inc.
  20. Radius is a trademark of Radius, Inc.
  21. Stacker is a registered trademark of STAC Electronics.
  22. Norton Anti-Virus is a registered trademark of Symantec Corporation.
  23. Zenith is a registered trademark of Zenith Electronics Corporation.
  24.  
  25. --------------------------------------------------------------------------
  26.  
  27. SETUP.TXT
  28. =========
  29.  
  30. This file contains information about problems that may occur while you are
  31. running Windows for Workgroups Setup or when you are using terminate-and-
  32. stay-resident (TSR) programs or drivers with Windows for Workgroups or Setup. 
  33. If you are using a TSR or if you encounter problems setting up Windows for 
  34. Workgroups, read this document BEFORE you run Setup again.
  35.  
  36.  
  37. GENERAL SETUP NOTES
  38. ====================
  39.  
  40. This section includes notes on specific system configurations that may
  41. prevent Setup from installing Windows for Workgroups successfully. A
  42. possible solution to each problem is provided.
  43.  
  44. If you are using a hardware or software product listed here, follow the
  45. proposed recommendations before you run Setup.
  46.  
  47.  
  48. Network Cards
  49. -------------
  50. If you are using one of the following network cards, you must run Setup 
  51. with the /i option:  
  52.  
  53.     Novell(R)/Anthem NE1500
  54.     Novell/Anthem NE2100
  55.     Advanced Micro Devices (AMD) AM2100
  56.     Microdyne Exos(R) 105
  57.  
  58. To do this, type the following at the MS-DOS prompt: 
  59.  
  60.     setup /i
  61.  
  62.  
  63. MS-DOS(R) Screen Savers
  64. -----------------------
  65. If you are using an MS-DOS screen saver, you should turn it off before
  66. running Setup. These screen savers can cause problems when running Setup.
  67.  
  68.  
  69. COMPAQ(R) Computer with MS-DOS Version 5.0 or later and EGA or VGA Display 
  70. -----------------------------------------------------------------
  71. If you are using the upgrade version of Microsoft MS-DOS 5.0 or later, check your
  72. CONFIG.SYS file to make sure the following drivers (if present) appear in
  73. this order:
  74.  
  75.     HIMEM.SYS 
  76.     EMM386.EXE
  77.     ANSI.SYS
  78.  
  79. Note: If you are using the COMPAQ version of MS-DOS 5.0, HIMEM.EXE is used 
  80.       in place of HIMEM.SYS and CEMM.EXE is used in place of EMM386.EXE.
  81.  
  82. If ANSI.SYS is loaded before HIMEM.SYS or EMM386.EXE (or if you are using
  83. COMPAQ MS-DOS 5.0 before HIMEM.EXE or CEMM.EXE), Setup may restart your
  84. system before Windows for Workgroups is installed. Also, if you are using
  85. the DOS=HIGH,UMB command line to load MS-DOS into upper memory, loading
  86. EMM386.EXE (or CEMM.EXE) before loading ANSI.SYS will create the maximum
  87. amount of upper memory space on a COMPAQ computer.
  88.  
  89.  
  90. AT&T(R) Safari Computer
  91. -----------------------
  92. If you have an AT&T Safari computer, you cannot maintain two versions of
  93. Windows on your system. You must upgrade over your previous version of
  94. Windows, if you have one. If you set up Windows for Workgroups version 3.11
  95. in its own directory, it will not use the special drivers required to run on the Safari
  96. computer.
  97.  
  98.  
  99. Displays That May Require Driver Updates with Windows for Workgroups
  100. --------------------------------------------------------------------
  101.  
  102. Certain third-party display drivers designed for Windows version 3.0 can
  103. cause problems with Windows for Workgroups version 3.11. The most serious
  104. problem is a system failure while you are running Windows for Workgroups 
  105. Setup. If you encounter this problem, run Custom Setup, and then select 
  106. one of the standard display types, such as VGA, that is provided with 
  107. Windows for Workgroups.
  108.  
  109. With other Windows version 3.0 display drivers, Windows for Workgroups may
  110. be set up successfully, but TrueType fonts may not appear correctly on your
  111. screen.
  112.  
  113. An updated driver may be available in the Windows Driver Library (WDL) or
  114. from your display vendor or manufacturer.  For information on obtaining drivers 
  115. from the WDL, see the "Getting Drivers from the Windows Driver Library 
  116. (WDL)" section later in this document.
  117.  
  118. Windows version 3.0 drivers for the following display adapters may cause
  119. problems:
  120.  
  121. * ATI Graphics Ultra, Vantage, and Mach32
  122.  
  123.   NOTE: These adapters are 8514/a-compatible and run well 
  124.         with the 8514/a driver provided with Windows for Workgroups.
  125.  
  126. * DGIS display adapters (Direct Graphics Interface Standard)
  127.   from Graphic Software Systems, including the following:
  128.         
  129.         NEC(R) MultiSynch Graphics Engine (MGE)
  130.         Zenith(R) Z-649             
  131.         HP(R) IGC-10, IGC-20
  132.         GSS 1000 Series 
  133.  
  134.   NOTE: Some DGIS-based adapters are TIGA-compatible and
  135.         run well when used with the appropriate TIGACD.EXE
  136.         MS-DOS driver and with the TIGA driver provided with 
  137.         Windows for Workgroups.
  138.  
  139. * HP Ultra VGA (versions earlier than 1.4 only)
  140. * IBM(R) Image Adapter/A  
  141. * Matrox MG Series/M-WIN Series
  142. * Palettized VGA 640x480, 16-color (provided with Windows
  143.   Multimedia Extensions version 1.0)
  144. * Radius(R) SVGA MultiView
  145.  
  146. * RGDI (Renaissance Graphics Device Interface) display
  147.   adapters from Appian, Inc., including the following:
  148.        Appian Rendition II, IIe, II/XE, and III
  149.        Appian GV1024
  150.        Decpc 433
  151.  
  152. - S3 adapters, including the following:
  153.       Orchid Fahrenheit 1280
  154.       STB WIND/X
  155.       Diamond Stealth VRAM
  156.  
  157.  
  158. Using the ATI Mach 32 Video Adapter
  159. -----------------------------------
  160. If you are using an ATI Mach 32 video adapter, you must use the 8514/a
  161. driver provided with Windows for Workgroups.
  162.  
  163. Before you run Windows Setup, make sure the Mach 32 adapter is set up 
  164. correctly. In the Mach 32 Install program, choose the Set Power-Up
  165. Configuration option. Set the VGA Memory Size to half the RAM
  166. available on the Mach 32 adapter. Since most Mach 32 adapters come with
  167. 1 MB of RAM, the appropriate setting is usually 512K. 
  168.  
  169. Using Stacker(R)
  170. ----------------
  171. If you are using Stacker to compress your hard disk, you need to take the
  172. following steps before setting up Windows for Workgroups.
  173.  
  174. *  If you want to use a swap file with Windows for Workgroups, you must
  175.    set up the swap file on the uncompressed drive. When you set up Stacker,
  176.    you can leave at least 1 MB of disk space uncompressed for storing system 
  177.    files. To leave enough space for the swap file, it is recommended that the
  178.    amount of uncompressed disk space equal at least twice the amount of 
  179.    system memory. For example, if your system has 4 MB of memory, you should
  180.    leave at least 8 MB of disk space uncompressed.
  181.  
  182.    If Stacker is already set up on your system and there is not enough
  183.    uncompressed disk space for a swap file, you can run the STAC utility
  184.    provided with Stacker to increase the amount of uncompressed disk space.
  185.    For more information, see your Stacker documentation.
  186.  
  187. *  If you are using Stacker version 2.0 or later, Windows for Workgroups
  188.    Setup modifies your CONFIG.SYS and AUTOEXEC.BAT files. When Setup
  189.    finishes making the modifications, it displays a message notifying you 
  190.    of the modifications. If you have used Stacker to swap your startup drive, 
  191.    when you restart your system Stacker will ask whether you want to update 
  192.    to the new version of the CONFIG.SYS or AUTOEXEC.BAT file. It is 
  193.    recommended that you update.
  194.  
  195.    If you are using a version of Stacker earlier than 2.0, you may need to
  196.    modify your CONFIG.SYS and AUTOEXEC.BAT files yourself. For more
  197.    information, see the following topic, "Modifying Your CONFIG.SYS and
  198.    AUTOEXEC.BAT Files Yourself."
  199.  
  200. *  For best performance, do not use SMARTDrive to cache the compressed drive.
  201.    You only need to cache the uncompressed drive. You can include options on
  202.    the SMARTDRV.EXE line of your CONFIG.SYS file to specify which drives to
  203.    cache.
  204.  
  205.    For example, if the Stacker swap utility swaps drives C and D, so that C
  206.    is compressed and D is uncompressed, you would include the following line
  207.    in your AUTOEXEC.BAT file:
  208.  
  209.         c:\windows\smartdrv.exe c- d+
  210.  
  211. For more information about swap files and using SMARTDrive, see Chapter 11,
  212. "Managing Memory and Performance," in the "Microsoft Windows for Workgroups
  213. User's Guide."
  214.  
  215.  
  216. Solving Memory Conflicts by Using MONOUMB.386 or MONOUMB2.386
  217. -------------------------------------------------------------
  218. If you encounter the following message when you start Windows for
  219. Workgroups, your display driver may be accessing the monochrome
  220. address range (B000-B7FF), which prevents the memory manager from
  221. using this range for upper memory blocks:
  222.  
  223.         "Windows cannot set up an upper memory block at segment B000.
  224.     Exclude this address space by using the syntax of your memory
  225.     manager. For more information, use an MS-DOS editor to read
  226.     the SETUP.TXT file." 
  227.  
  228. To solve this problem, try installing MONOUMB2.386 on your system. 
  229. MONOUMB2.386 is a device driver that allows certain memory managers to use
  230. the monochrome address range for upper memory blocks even if your display
  231. driver is accessing this range. 
  232.  
  233. You can get MONOUMB2.386 from Windows for Workgroups 3.1 or from Microsoft. 
  234. It is not included on the Windows for Workgroups 3.11 disks. To install
  235. MONOUMB2.386, carry out the following procedure:
  236.  
  237. 1.  Copy and expand the MONOUMB2.38_ file to your Windows SYSTEM directory
  238.     by typing the following at the MS-DOS prompt:
  239.  
  240.     expand  a:\monoumb2.38_  c:\windows\system\monoumb2.386
  241.  
  242. 2.  Add the following setting to the [386Enh] section of your SYSTEM.INI
  243.     file:
  244.  
  245.     device=monoumb2.386
  246.  
  247. 3.  Start Windows for Workgroups.
  248.  
  249. Note: MONOUMB2.386 may not work with some memory managers, such as
  250.       EMM386.EXE. In this case, you can try using MONOUMB.386, provided
  251.       with the Windows Driver Library (WDL). For information on obtaining 
  252.       drivers from the WDL, see the "Getting Drivers from the Windows Driver
  253.       Library (WDL)" section later in this document.
  254.  
  255. You can also exclude the address region B000-B7FF. This specifies that the
  256. memory manager should not try to use this address range for upper memory
  257. blocks.  For information about excluding specific address ranges, see the
  258. following topic.
  259.  
  260.  
  261. Solving Memory Conflicts by Excluding an Address Range
  262. ------------------------------------------------------
  263. If you encounter the following message when you start Windows for
  264. Workgroups, and the address specified in the message is not B000,
  265. you must exclude the address range:
  266.  
  267.         "Windows cannot set up an upper memory block at segment xxxx.
  268.     Exclude this address space by using the syntax of your memory
  269.     manager. For more information, use an MS-DOS editor to read
  270.     the SETUP.TXT file."
  271.  
  272. If the address specified in the message is B000, you can try installing
  273. MONOUMB2.386 or MONOUMB.386, as described in the preceding topic.
  274.  
  275. The method you use to exclude an address range depends on the memory manager
  276. you are using. For example, if you are using EMM386.EXE, you need to remove
  277. the I=xxxx option from the device=emm386.exe command line in your CONFIG.SYS
  278. file, where xxxx is the address range starting at the address specified in
  279. the error message.
  280.  
  281. If you are using QEMM, you need to include the X= option on the
  282. device=qemm386.sys command line in your CONFIG.SYS file. For example, to
  283. exclude the address range C000-C7FF, you would specify the following: 
  284.  
  285.         device=qemm386.sys  X=C000-C7FF
  286.  
  287. For more information about modifying your CONFIG.SYS file, see your MS-DOS
  288. documentation. For more information about installing and configuring
  289. EMM386.EXE, see "Managing Memory and Performance" in your Windows or Windows
  290. for Workgroups user's guide. For information about installing and configuring
  291. other memory managers, see the documentation provided with your memory
  292. manager.
  293.  
  294.  
  295. Modifying Your CONFIG.SYS and AUTOEXEC.BAT Files Yourself
  296. ---------------------------------------------------------
  297. When you set up Windows for Workgroups, Setup usually places the HIMEM.SYS,
  298. SMARTDRV.EXE, and EMM386.EXE files in the Windows directory. If the Windows
  299. directory is on a disk that is not available when you start your computer,
  300. such as a removable or nonlocal disk, or if Setup detects one of the
  301. following conditions, Setup does not modify your CONFIG.SYS or AUTOEXEC.BAT
  302. file:
  303.  
  304. * Your boot drive has been modified by a disk-compression utility.
  305.  
  306. * Your CONFIG.SYS file contains references to block device drivers.
  307.  
  308. * Your CONFIG.SYS file is set up for multiple configurations.
  309.  
  310. * There is not enough available space on your hard disk to copy the files.
  311.  
  312. * The files are already installed on your system, and Setup cannot overwrite 
  313.   them (they are read-only).
  314.  
  315. Instead, Setup writes proposed changes to the CONFIG.WIN and AUTOEXEC.WIN or
  316. the CONFIG.00x and AUTOEXEC.00x files. In this case, you must either move
  317. the HIMEM.SYS, SMARTDRV.EXE, and EMM386.EXE files to a drive that is
  318. available when you start your computer, or use a text editor to modify your
  319. CONFIG.SYS or AUTOEXEC.BAT file so that any references to HIMEM.SYS,
  320. SMARTDRV.EXE, and EMM386.EXE appear after the device= command line used to
  321. load the drivers for your disk drives. Refer to the CONFIG.WIN and
  322. AUTOEXEC.WIN or the CONFIG.00x and AUTOEXEC.00x files for the proposed
  323. changes.
  324.  
  325.  
  326. Setting Up an XGA Video Adapter on a PS/2(R) Model 75 or 90
  327. -----------------------------------------------------------
  328. If you have a PS/2 model 75 or 90 with an XGA video adapter, Windows for
  329. Workgroups Setup will configure the display adapter for 16-color, 640x480
  330. resolution. Do not change this configuration during Setup. Specifying a
  331. different XGA configuration while setting up Windows for Workgroups may 
  332. cause Setup to fail.
  333.  
  334. After you have successfully installed Windows, you can configure your XGA to
  335. use a different resolution or 256 colors, if your monitor supports it. For
  336. more information on how to do this, see the topic "IBM XGA: Configuring
  337. Color and Resolution" in the README.WRI online document.
  338.  
  339. If you are using the plasma screen on the PS/2 model 75, use ONLY the
  340. 640x480, 16-color configuration. If you change this configuration, you
  341. return to the MS-DOS prompt when you try to start Windows.
  342.  
  343.  
  344. Setting up an IBM Token Ring 4/16Mbs Network Card on a Microchannel (MCA) Computer 
  345. ---------------------------------------------------------------------------
  346. If you have a Microchannel computer, and you are installing Windows for Workgroups 
  347. support for the IBM Token Ring 4/16Mbs network card, you must make sure the 
  348. Maximum Transmits parameter is set no higher than 1024. If you try to use a higher 
  349. value, the network card will not work with your computer.
  350.  
  351.  
  352. Correcting the "Out of Environment Space" Error Message
  353. -------------------------------------------------------
  354. If you receive an "out of environment space" message when starting Windows,
  355. you can solve the problem in either of two ways:
  356.  
  357. *  Increase the size of your environment by adding the SHELL= command
  358.    line to your CONFIG.SYS file. See your MS-DOS documentation for more
  359.    information about the SHELL command and about modifying your CONFIG.SYS
  360.    file.
  361.  
  362. *  Move the SET commands in your AUTOEXEC.BAT file to the beginning of
  363.    the file so that they run before the commands that load
  364.    terminate-and-stay-resident (TSR) programs or drivers, such as
  365.    SMARTDrive.
  366.  
  367.  
  368. Using Multimedia Extensions Version 1.0 with Windows for Workgroups
  369. -------------------------------------------------------------------
  370. To use the Multimedia Extensions with Windows for Workgroups, first
  371. set up Windows with Multimedia Extensions version 1.0. Then upgrade to 
  372. Windows for Workgroups by installing it into the same directory. If 
  373. you set up Windows for Workgroups before setting up Multimedia 
  374. Extensions, not all the files will be properly installed.
  375.  
  376. See the README.WRI online document for more information about running
  377. Multimedia Extensions with Windows for Workgroups.
  378.  
  379. Getting Drivers from the Windows Driver Library (WDL)
  380. ============================================================
  381.  
  382. If you have a modem, you can download Windows Driver Library files from network services, including CompuServe«,  GEnieÖ, Microsoft OnLine, or various user-group bulletin boards (such as the bulletin-board services on the Association of PC User Groups network). If you have a modem, you can download Windows Driver Library components from network services, including CompuServe«,  GEnieÖ, Microsoft OnLine, or various user-group bulletin boards (such as the bulletin-board services on the Association of PC User Groups network). Files from the Windows Driver Library is also available from Microsoft Download Service (MSDL), which you can reach by calling (206) 936-MSDL (936-6735) any time except between 1:00 A.M. and 2:30 A.M. Pacific time. To use MSDL, use the following communications settings:
  383. Baud rate
  384. 1200, 2400, or 9600
  385. Data bits
  386. 8
  387.  
  388. Parity
  389. None
  390. Stop bits
  391. 1
  392.  
  393.  
  394. People within the United States who do not have a modem can order individual files on disks from the Windows Driver Library by calling Microsoft Product Support Services at (206) 637-7098 or (206) 635-4948 (text telephone).
  395.  
  396.  
  397.  
  398. USING TERMINATE-AND-STAY-RESIDENT (TSR) PROGRAMS AND DRIVERS
  399. WITH WINDOWS FOR WORKGROUPS
  400. ============================================================
  401.  
  402. The "Program Listing" section of this document lists a number of terminate-
  403. and-stay-resident (TSR) programs and drivers that are known to cause
  404. problems when running with Windows for Workgroups. Some of the problems
  405. you may encounter include system failures or incorrect screen displays.
  406. In some cases, we have included solutions or workarounds for the problems.
  407.  
  408. When you install Windows for Workgroups, Setup searches your AUTOEXEC.BAT
  409. and CONFIG.SYS files for references to TSR programs and drivers and scans
  410. memory for TSRs that are currently running. If Setup detects a TSR that is
  411. known to cause problems when running with Windows for Workgroups, a message
  412. appears asking whether you want to continue or quit Setup.
  413.  
  414. If you receive such a message, carry out the following procedure:
  415.  
  416. 1. Locate your TSR in the "Program Listing" section of this document.
  417.    Determine whether the situation prevents Setup from successfully
  418.    installing Windows for Workgroups.
  419.  
  420. 2. If the situation does not affect Setup, continue setting up Windows for 
  421.    Workgroups by following the instructions on your screen.
  422.    
  423.    If the situation does affect Setup and prevents it from installing
  424.    Windows for Workgroups, quit Setup, and then carry out the following
  425.    steps.
  426.  
  427. 3. Quit the TSR and remove all references to it from your AUTOEXEC.BAT and 
  428.    CONFIG.SYS files. For more information, see the documentation for your
  429.    TSR.
  430.  
  431. 4. Restart your computer.
  432.  
  433. 5. Run Windows for Workgroups Setup again.
  434.  
  435. After Windows for Workgroups is successfully set up, you may want to
  436. restore your TSRs. 
  437.  
  438. Setup cannot detect all the TSRs or drivers included in the "Program
  439. Listing" section. The TSRs and drivers that Setup can detect are listed
  440. in the in the [incomptsr1] and [incomptsr2] sections of the SETUP.INF
  441. file.
  442.  
  443.  
  444. PROGRAM LISTING
  445. ===============
  446.  
  447. This section describes some problems that you might encounter while using a 
  448. TSR with Windows for Workgroups. It does not include all possible problems 
  449. that can occur.
  450.  
  451.  
  452. 386MAX(R) 
  453. ---------
  454. The documentation for 386MAX recommends against setting the EXT parameter
  455. below 64. If you set this parameter to 0, Setup will fail.
  456.  
  457. See the README.WRI online document for more information about running 386MAX
  458. with Windows for Workgroups.
  459.  
  460.  
  461. 386MAX Disk-Cache Utility (QCACHE.EXE)
  462. --------------------------------------
  463. Do not use this disk-cache utility simultaneously with SMARTDrive. There is
  464. no reason to use two disk-cache utilities with Windows for Workgroups. It is
  465. recommended that you use SMARTDrive, provided with Windows for Workgroups,
  466. instead.
  467.  
  468.  
  469. All Charge 386 Version 3.1 
  470. -------------------------- 
  471. ALLEMM4.SYS is a memory manager that causes problems with Setup and Windows
  472. for Workgroups. If you encounter problems running this program with Windows
  473. for Workgroups, it is recommended that you use EMM386.EXE and HIMEM.SYS,
  474. provided with Windows for Workgroups, to manage memory instead.
  475.  
  476.  
  477. Anarkey Version 4.00
  478. --------------------
  479. Do not run Windows for Workgroups when Anarkey version 4.00 is running. With 
  480. some memory configurations, running Anarkey version 4.00 with Windows for 
  481. Workgroups may cause unpredictable system failures. In rare cases, this 
  482. program can also corrupt hard-disk data. Also, Windows for Workgroups might 
  483. not start when this program is running.
  484.  
  485. Version 4.01 may correct these problems. Contact Moderne Software for a free
  486. upgrade to Anarkey 4.01.
  487.  
  488.  
  489. Anarkey Version 4.01
  490. --------------------
  491. Do not load Anarkey HIGH before starting Windows for Workgroups. If you load 
  492. Anarkey HIGH, your system may fail when you try to start an application.
  493.  
  494.  
  495. APPEND (MS-DOS)
  496. ---------------
  497. Do not use the APPEND utility with Windows for Workgroups. It prevents
  498. Windows and Windows-based applications from creating valid Well-Formed-Path
  499. (WFP) names for the files they are using. (A WFP is the complete name of a
  500. file, including the drive letter and full path specification, starting from
  501. the root directory.)
  502.  
  503.  
  504. ASP Integrity Toolkit Version 3.7
  505. ---------------------------------
  506. This virus-protection program can cause problems when you are running Windows
  507. for Workgroups Setup, including system failure, automatic restarting of the 
  508. system, and keyboard failure. You should turn off protection in the Toolkit 
  509. before you set up Windows for Workgroups. For information about how to do 
  510. this, see your ASP Integrity documentation.
  511.  
  512.  
  513. Autocon Version 2.0e 
  514. --------------------
  515. Autocon enables you to select up to 50 different configurations when you
  516. start your system. To do this, it modifies your CONFIG.SYS and AUTOEXEC.BAT 
  517. files, based on information in its database (AUTOCON.DAT), when you restart 
  518. your system from within Autocon.
  519.  
  520. Windows for Workgroups Setup modifies only the first section in your 
  521. CONFIG.SYS and AUTOEXEC.BAT files. If you want to use specific
  522. configurations with Windows, you must run Autocon and then manually
  523. edit the configurations in the database that you want to use. You
  524. must do this after setting up Windows for Workgroups. For your changes
  525. to take effect, you must restart your system from within Autocon. For
  526. more information, see your Autocon documentation.
  527.  
  528.  
  529. Bootcon Version 1.60
  530. --------------------
  531. Bootcon enables you to maintain different system-configuration information
  532. in your CONFIG.SYS and AUTOEXEC.BAT files. You can then select the
  533. configuration you want to use from a menu when you start your system.
  534.  
  535. Setup modifies the first section in your CONFIG.SYS and AUTOEXEC.BAT
  536. files and may modify certain other sections that contain network drivers
  537. (for example, LAN Manager drivers and NetWare drivers may be deleted). After
  538. you set up Windows for Workgroups, you must edit the sections of those files
  539. that contain other configurations you want to use. For more information, see
  540. your Bootcon documentation.
  541.  
  542.  
  543. BOOT.SYS
  544. --------
  545. BOOT.SYS enables you to maintain different system-configuration information
  546. in your CONFIG.SYS and AUTOEXEC.BAT files. You can then select the
  547. configuration you want to use from a menu when you start your system.
  548.  
  549. Setup modifies the first section in your CONFIG.SYS and AUTOEXEC.BAT
  550. files and may modify certain other sections that contain network drivers
  551. (for example, LAN Manager drivers and NetWare drivers may be deleted). After
  552. you set up Windows for Workgroups, you must edit the sections of those files
  553. that contain other configurations you want to use. For more information, see
  554. your BOOT.SYS documentation.
  555.  
  556.  
  557. CACHE.EXE Disk-Cache Utility
  558. ----------------------------
  559. Do not use two disk-cache utilities with Windows for Workgroups. It is
  560. recommended that you use SMARTDrive, provided with Windows for Workgroups,
  561. and remove all references to other disk-cache utilities from your CONFIG.SYS
  562. and AUTOEXEC.BAT files. (If CACHE.EXE is detected, Setup removes it from your
  563. CONFIG.SYS file for you.)
  564.  
  565.  
  566. CACHE.SYS Disk-Cache Utility
  567. ----------------------------
  568. This disk-cache utility will not work properly with SMARTDrive. It is
  569. recommended that you use SMARTDrive, provided with Windows for Workgroups,
  570. and remove all references to other disk-cache utilities from your
  571. CONFIG.SYS and AUTOEXEC.BAT files. (If CACHE.SYS is detected, Setup removes
  572. it from your CONFIG.SYS file for you.)
  573.  
  574.  
  575. CED Version 1.0e
  576. ----------------
  577. Using CED with Windows for Workgroups may cause problems, including
  578. system failure. It is recommended that you do not use CED with Windows for
  579. Workgroups.
  580.  
  581.  
  582. Central Point Anti-Virus Version 1.1 (VSAFE.COM/VSAFE.SYS)
  583. ----------------------------------------------------------
  584. VSAFE.COM/VSAFE.SYS should not be loaded when you set up Windows for
  585. Workgroups. Otherwise, Setup may not run properly. After you set up
  586. Windows for Workgroups, you can load VSAFE.
  587.  
  588. If you are upgrading to Windows for Workgroups 3.11, you must also 
  589. delete all the CHKLIST.MS files that VSAFE  has created before you run Setup. 
  590.  
  591. Because Windows uses the disk for memory swapping, you should turn off the
  592. VSAFE write-protection option when you run Windows for Workgroups.
  593.  
  594. For more information, see the Central Point Anti-Virus documentation.
  595.  
  596.  
  597. CMDEDIT.COM Version 2.0
  598. -----------------------
  599. If this command-line editor is loaded before Windows for Workgroups is
  600. started, it may cause a General Protection Fault when you run multiple
  601. MS-DOS Prompts.
  602.  
  603.  
  604. Cubit Version 3.01
  605. ------------------
  606. When you are using Cubit with Windows for Workgroups, do not compress the
  607. Windows SYSTEM directory or any file that is loaded from your CONFIG.SYS
  608. file. Compressing these files could cause problems.
  609.  
  610. Before you upgrade to Windows for Workgroups, make sure that the earlier
  611. version of Windows is uncompressed on your hard disk. You may recompress the
  612. files after you have successfully set up Windows for Workgroups.
  613.  
  614.  
  615. Data Physician Plus Version 2.0 (VirALERT)
  616. ------------------------------------------
  617. It is recommended that you do not set up Windows for Workgroups while
  618. VirALERT is running. If you do, VirALERT will display a warning message
  619. every few seconds while Setup is running.
  620.  
  621. After you have set up Windows for Workgroups, you can run VirALERT. Press
  622. ALT+V to display the VirALERT menu. You can use the commands on this menu to
  623. disable and enable VirALERT.
  624.  
  625.  
  626. DOSCUE.COM Command-Line Editor
  627. ------------------------------
  628. The DOSCUE command-line editor produces unexpected results when used with
  629. Windows for Workgroups. It is recommended that you do not use this editor
  630. with Windows for Workgroups.
  631.  
  632.  
  633. Doubledisk Version 2.5
  634. ----------------------
  635. Windows for Workgroups may try to access "phantom" disk drives if you use it
  636. with Doubledisk. Phantom drives occur when you use Doubledisk to create a
  637. compressed drive. For example, if you have drives A, B, and C on your
  638. computer and you use Doubledisk to create drive F, Windows for Workgroups
  639. and MS-DOS recognize drives D and E as valid drives, even though they do
  640. not actually exist. You can use the DRVOFF utility to prevent Windows from
  641. recognizing phantom drives. Contact Vertisoft to order a copy of the DRVOFF
  642. utility.
  643.  
  644.  
  645. Fastopen (MS-DOS)
  646. -----------------
  647. Fastopen is a RAM-resident utility. Problems involving the file allocation
  648. table (FAT) may occur if Fastopen is used with disk-defragmenting utilities. 
  649. In low-memory situations, you may need to remove Fastopen for Windows for 
  650. Workgroups to run properly.
  651.  
  652.  
  653. Flash Disk-Cache Utility (FLASH.EXE)
  654. ------------------------------------
  655. Do not use this disk-cache utility simultaneously with SMARTDrive. There is
  656. no reason to use two disk-cache utilities with Windows for Workgroups. It is
  657. recommended that you use SMARTDrive, provided with Windows for
  658. Workgroups, instead.
  659.  
  660.  
  661. Graphics (MS-DOS)
  662. -----------------
  663. Loading Graphics from MS-DOS Prompt within Windows can cause unexpected
  664. results when you are printing. The active MS-DOS Prompt will send its 
  665. output to the printer. Switching between multiple MS-DOS Prompts may 
  666. result in mixed printing jobs.
  667.  
  668.  
  669. HPEMM386.SYS and HPEMM486.SYS
  670. -----------------------------
  671. These expanded-memory managers are incompatible with Windows for Workgroups.
  672. It is recommended that you use EMM386.EXE to manage memory instead.
  673.  
  674.  
  675. HPMM.SYS - HP Memory Manager
  676. ----------------------------
  677. When HPMM.SYS is running, you cannot set up Windows for Workgroups. 
  678. You should remove all references to HPMM.SYS from your CONFIG.SYS 
  679. and AUTOEXEC.BAT files before setting up Windows for Workgroups.
  680.  
  681.  
  682. Hyperdisk Disk-Cache Utility 
  683. ----------------------------
  684. Do not use this disk-cache utility simultaneously with SMARTDrive. There is
  685. no reason to use two disk-cache utilities with Windows for Workgroups. It is
  686. recommended that you use SMARTDrive, provided with Windows for Workgroups,
  687. instead.
  688.  
  689.  
  690. IBM VDISK.SYS (RAM Disk Utility)
  691. --------------------------------
  692. VDISK.SYS is incompatible with Windows for Workgroups because it occupies
  693. extended memory required to run Windows for Workgroups. This utility prevents
  694. any XMS-compatible memory manager from loading.
  695.  
  696.  
  697. IEMM.SYS Memory Manager
  698. -----------------------
  699. The IEMM.SYS memory manager is incompatible with Windows for Workgroups. It
  700. is recommended that you remove all references to IEMM.SYS from your
  701. CONFIG.SYS and AUTOEXEC.BAT files and use EMM386.EXE, provided with Windows
  702. for Workgroups, to manage memory instead.
  703.  
  704.  
  705. ICACHE.SYS Disk-Cache Utility
  706. -----------------------------
  707. Do not use two disk-cache utilities with Windows for Workgroups.
  708. It is recommended that you use SMARTDrive, provided with Windows for
  709. Workgroups, and remove all references to other disk-cache utilities from
  710. your CONFIG.SYS and AUTOEXEC.BAT files. (If ICACHE.SYS is detected, Setup
  711. removes it from your CONFIG.SYS file for you.)
  712.  
  713.  
  714. IBMCACHE.SYS Disk-Cache Utility
  715. -------------------------------
  716. Do not use two disk-cache utilities with Windows for Workgroups.
  717. It is recommended that you use SMARTDrive, provided with Windows for
  718. Workgroups, and remove all references to other disk-cache utilities from
  719. your CONFIG.SYS and AUTOEXEC.BAT files. (If IBMCACHE.SYS is detected, Setup
  720. removes it from your CONFIG.SYS file for you.)
  721.  
  722.  
  723. Intel(R) Expanded-Memory Emulator (ILIM386.SYS)
  724. -----------------------------------------------
  725. The ILIM386.SYS expanded-memory emulator, provided with the Intel
  726. Inboard(TM)/386 product, is incompatible with Windows for Workgroups. It is
  727. recommended that you remove all references to this emulator from your
  728. CONFIG.SYS and AUTOEXEC.BAT files before setting up Windows for Workgroups.
  729.  
  730.  
  731. JOIN (MS-DOS)
  732. -------------
  733. Do not add or remove "joined" drives while you are running Windows for 
  734. Workgroups. If you use the JOIN command before starting Windows for 
  735. Workgroups and do not change the state of the joined drives from MS-DOS 
  736. Prompt within Windows, Windows for Workgroups will work properly. It is 
  737. recommended that you do not use joined drives at all if you plan to run 
  738. Windows.
  739.  
  740.  
  741. KEYB.COM (MS-DOS)
  742. -----------------
  743. If you use command-line options to load KEYB.COM, it is recommended that you
  744. load it before starting Windows for Workgroups. After it is loaded, you can
  745. change the keyboard configuration from MS-DOS Prompt within Windows at any
  746. time. If you do not load KEYB.COM before starting Windows, you may encounter
  747. problems when using a KEYB command that includes an option in an MS-DOS
  748. Prompt. However, you can use the KEYB command without options at any time to
  749. display code-page information.
  750.  
  751.  
  752. LANSight(TM) Version 2.0
  753. ------------------------
  754. LANSight is a utility that you can use to control and monitor other
  755. workstations attached to a Novell network. In some cases, version 2.0 of
  756. LANSight may cause the workstation running Windows for Workgroups to
  757. fail.
  758.  
  759.  
  760. Lasertool Control Panel Version 2.2
  761. -----------------------------------
  762. If you load version 2.2 of the Lasertool Control Panel program (PCPANEL.EXE)
  763. from Windows for Workgroups, your system may fail. This program works
  764. properly if you load it before you start Windows for Workgroups.
  765.  
  766.  
  767. Le Menu Version 1.0
  768. -------------------
  769. When you are using Le Menu version 1.0 with Windows for Workgroups, 
  770. environment information such as PATH, PROMPT, and WINDIR may be lost if you 
  771. start MS-DOS Prompt from within Windows. If you want to start Windows for 
  772. Workgroups by using a Le Menu menu command, it is recommended that you set 
  773. up Windows for Workgroups as a Batch-File menu command so that COMMAND.COM 
  774. will load before starting Windows for Workgroups. For more information, see 
  775. your Le Menu documentation.
  776.  
  777.  
  778. LOCKIT Version 3.3 (PC Vault, Secure It)
  779. ----------------------------------------
  780. Version 3.3 of these programs strips out spaces from the load= command line
  781. in the WIN.INI file. Later versions may correct this problem.
  782.  
  783.  
  784. Logitech(TM) Mouse Software Version 5.0/6.0 (CLICK, LOGIMENU)
  785. -------------------------------------------------------------
  786. If you want to use CLICK and LOGIMENU from MS-DOS Prompt within Windows, you
  787. must load the TSRs from that MS-DOS Prompt, even if you loaded the TSRs
  788. before starting Windows for Workgroups. When you quit Windows for
  789. Workgroups, you must reload the TSRs for them to work properly from the
  790. command prompt outside of Windows, even if you loaded them from MS-DOS
  791. Prompt within Windows.
  792.  
  793.  
  794. Mace Disk-Cache Utility (MCACHE.SYS)
  795. ------------------------------------
  796. This disk-cache utility will not work properly with SMARTDrive. It is
  797. recommended that you use SMARTDrive, provided with Windows for Workgroups,
  798. and remove all references to other disk-cache utilities from your
  799. CONFIG.SYS and AUTOEXEC.BAT files. (If Mace is detected, Setup removes it
  800. from your CONFIG.SYS file for you.)
  801.  
  802.  
  803. Maximizer Memory Manager (MAXIMIZE.COM)
  804. ---------------------------------------
  805. If you are using the Maximizer memory manager, you may not be able to set up
  806. or start Windows for Workgroups. Make sure that you are using only one
  807. memory manager with Windows for Workgroups. It is recommended that you use
  808. HIMEM.SYS and EMM386.EXE, which are provided with Windows for Workgroups, to
  809. manage memory instead.
  810.  
  811.  
  812. Mirror (MS-DOS)
  813. ---------------
  814. If you run Mirror from Windows for Workgroups by using the Run command 
  815. or from a command line within an MS-DOS box, it creates an inaccurate
  816. MIRROR.FIL file. You should run Mirror only before you run Windows. 
  817.  
  818. If you run Mirror with the /t option and then start Windows, you cannot 
  819. remove it from memory by using the MIRROR /u command until you exit Windows. 
  820. This will cause an error message to appear.
  821.  
  822.  
  823. NDOSEDIT.COM
  824. ------------
  825. You may have problems loading this command-line editor. Also, it may cause
  826. unexpected results when running with Windows for Workgroups.
  827.  
  828.  
  829. NetRoom Memory Manager (RM386.SYS)
  830. ----------------------------------
  831. With some older versions of NetRoom, you may encounter problems setting up
  832. Windows for Workgroups. In this case, contact Helix Software for the most
  833. current version of NetRoom.
  834.  
  835.  
  836. NetWare(R) NetBIOS
  837. ------------------
  838. The NetWare NetBIOS TSR is incompatible with Windows for Workgroups in
  839. many configurations. In most cases, Setup will detect NetWare NetBIOS and
  840. remove the startup command from your system. However, if you have NetWare
  841. NetBIOS set up to start from a location other than your AUTOEXEC.BAT file
  842. (for example, from a batch file), Setup cannot detect it. In this case, you
  843. need to remove NetWare NetBIOS manually. Windows for Workgroups 3.11 
  844. includes an IPX/SPX compatible protocol that you can use instead of NetBIOS.
  845. For information about configuring Windows for Workgroups to work with it, see the
  846. NETWORKS.WRI online document.
  847.  
  848.  
  849. Newspace Version 1.07
  850. ---------------------
  851. This disk-compression utility is incompatible with Windows for Workgroups
  852. and may cause several problems.
  853.  
  854.  
  855. Norton Anti-Virus(R) Version 1.0
  856. --------------------------------
  857. If you load version 1.0 of Anti-Virus before you set up Windows for
  858. Workgroups, Setup may fail. It is recommended that you contact Symantec for
  859. the most current version of this program.
  860.  
  861.  
  862. Norton Desktop for Windows (EP.EXE)
  863. -----------------------------------
  864. If the data-recovery program Erase Protect (EP.EXE) is loaded from your
  865. AUTOEXEC.BAT file, you need to disable it when you are setting up Windows 
  866. for Workgroups, especially if you are upgrading over a previous version of
  867. Windows. Erase Protect tries to save copies of all deleted files, which can
  868. cause you to run out of disk space while running Setup.
  869.  
  870. It is recommended that you run Erase Protect with a permanent swap file. 
  871. If you are using a temporary swap file, you need to exclude files that have 
  872. a .TMP or .SWP extension from erase protection.
  873.  
  874.  
  875. Norton Utilities(R) Version 5.0 (DISKREET, NCACHE)
  876. --------------------------------------------------
  877. This program is incompatible with Windows for Workgroups and may cause your
  878. system to fail. It is recommended that you upgrade to the most recent
  879. version of Norton Utilities to correct problems.
  880.  
  881.  
  882. Norton Utilities Version. 6.01 (NCACHE)
  883. ---------------------------------------
  884. Some versions of NCACHE may prevent you from setting up or starting Windows
  885. for Workgroups. This is more likely to happen if NCACHE is set up as an EMS
  886. cache. Setting up NCACHE as an XMS cache instead may solve the problem.
  887.  
  888. You may also encounter additional problems using NCACHE. New versions may
  889. correct these problems. For an updated version of NCACHE, contact Symantec
  890. Corporation. In the meantime, you can use SMARTDrive, which is provided with
  891. Windows for Workgroups.
  892.  
  893.  
  894. Norton Utilities Version 6.01 (DISKMON)
  895. ---------------------------------------
  896. It is recommended that you do not use DISKMON version 6.01 with Windows for
  897. Workgroups.
  898.  
  899.  
  900. PCED Version 2.00
  901. -----------------
  902. Do not load the PCED command-line editor HIGH. Loading it HIGH may cause
  903. unexpected results, such as system failures, when Windows for Workgroups is
  904. running. 
  905.  
  906.  
  907. PCKEY.EXE (MultiSoft Keyboard Enhancer and Command-Line Stack)
  908. --------------------------------------------------------------
  909. PCKEY.EXE may not work properly with Windows for Workgroups when you are
  910. running more than one MS-DOS--based application at a time. It is recommended
  911. that you unload PCKEY.EXE before starting Windows for Workgroups.
  912.  
  913.  
  914. PC-Kwik Disk Accelerator
  915. ------------------------
  916. If you use PC-Kwik with Windows for Workgroups, make sure that you are 
  917. using version 3.55 or later and that PC-Kwik is in extended memory, not 
  918. expanded memory. To get an upgraded version of PC-Kwik, contact MultiSoft.
  919.  
  920.  
  921. PC-Kwik Disk-Cache Utility (PC-KWIK.EXE)
  922. ----------------------------------------
  923. Do not use this disk-cache utility simultaneously with SMARTDrive. There is
  924. no reason to use two disk-cache utilities with Windows for Workgroups. It is
  925. recommended that you use SMARTDrive, provided with Windows for Workgroups,
  926. instead.
  927.  
  928.  
  929. PC-Kwik Version. 1.59 (PCK.EXE, PSKSCRN.EXE, PCKEY.COM)
  930. -------------------------------------------------------
  931. If version 1.59 of PC-KWIK is loaded before setting up Windows for
  932. Workgroups, Setup may fail. PC-KWIK Version 2.0 may correct this problem.
  933.  
  934.  
  935. PCSXMAEM.SYS Utility
  936. --------------------
  937. This utility is incompatible with Windows for Workgroups. You should remove
  938. all references to it from your CONFIG.SYS and AUTOEXEC.BAT files before
  939. setting up or starting Windows for Workgroups. PCSXMAEM.SYS is similar
  940. to XMAEM.SYS. It has been renamed and slightly modified. It is provided with
  941. current versions of the IBM PC/3270 emulator.
  942.  
  943.  
  944. PCSX2EMS.SYS
  945. ------------
  946. Windows for Workgroups will run correctly with PCSX2EMS.SYS if it is loaded
  947. on a computer that has an XMA board installed. Otherwise, this program is
  948. incompatible with Windows for Workgroups. PCSX2EMS.SYS is provided with the
  949. IBM PC/3270 emulator.
  950.  
  951.  
  952. PC Tools Deluxe(TM) Version 7.1 (DATAMON)
  953. -----------------------------------------
  954. If you load PC Tools DATAMON using the \SENTRY+ option, Setup may fail if
  955. you are low on disk space. Do not use the \SENTRY+ option when loading
  956. DATAMON.
  957.  
  958. Do not load DATAMON after loading SMARTDrive. If DATAMON is loaded after
  959. SMARTDrive, your system may fail. See the PC Tools documentation for
  960. information about how to unload DATAMON.
  961.  
  962.  
  963. PC Tools Deluxe Version 6.0 (DESKTOP)
  964. -------------------------------------
  965. If you try to start PC Tools from a MS-DOS Prompt within Windows for
  966. Workgroups, your system may fail or restart itself. These problems also 
  967. occur if you use MS-DOS commands from a MS-DOS Prompt within Windows.
  968.  
  969. Version 7.0 of PC Tools may correct these problems. However, do not load
  970. DESKTOP from a MS-DOS Prompt if it was loaded before starting Windows for
  971. Workgroups. If you do, your system may fail when you quit Windows for
  972. Workgroups. It is recommended that you run DESKTOP from its PIF, provided
  973. with Windows for Workgroups.
  974.  
  975.  
  976. PC Tools Deluxe Version 7.1 (VDEFEND)
  977. -------------------------------------
  978. Setup may not work properly if VDEFEND is loaded before running Setup. You
  979. may load VDEFEND after setting up Windows for Workgroups.
  980.  
  981.  
  982. PC Tools(TM) Disk-Cache Utility (PC-CACHE.COM)
  983. ----------------------------------------------
  984. Do not use this disk-cache utility simultaneously with SMARTDrive. There is
  985. no reason to use two disk-cache utilities with Windows. It is recommended
  986. that you use SMARTDrive, provided with Windows for Workgroups, instead.
  987.  
  988.  
  989. PRINT (MS-DOS)
  990. --------------
  991. If you are printing several large documents on a network printer and run
  992. Setup from the network, your system may fail while Setup is creating Program
  993. Manager groups.
  994.  
  995.  
  996. PYRO! Version 1.0
  997. -----------------
  998. If this screen saver is loaded before starting Windows for Workgroups,
  999. you may not be able to restore the Windows for Workgroups screen after
  1000. this screen saver appears.
  1001.  
  1002.  
  1003. QMAPS Memory Manager Version 5.16
  1004. ---------------------------------
  1005. If you are using the QMAPS memory manager, you may not be able to set up or
  1006. start Windows for Workgroups. New versions may correct these problems. For
  1007. an updated version of QMAPS, contact Quadtel. In the meantime, you can use
  1008. HIMEM.SYS and EMM386.EXE, provided with Windows for Workgroups, to manage
  1009. memory instead.
  1010.  
  1011.  
  1012. RAMTYPE.SYS - AST RAMpage!(R) Boards
  1013. ------------------------------------
  1014. The RAMTYPE.SYS driver is incompatible with Windows for Workgroups. It is
  1015. recommended that you remove this driver before setting up Windows for
  1016. Workgroups. If you load the driver from your CONFIG.SYS file, comment
  1017. out the command line for the driver as follows:
  1018.  
  1019.    rem RAMTYPE.SYS 
  1020.  
  1021. Windows for Workgroups will run correctly without RAMTYPE.SYS. However,
  1022. other drivers that rely on RAMTYPE.SYS will not load and applications will
  1023. not be able to use the expanded memory on your system.
  1024.  
  1025. After you set up Windows for Workgroups, you can use version 1.2 and later
  1026. of RAMTYPE.SYS with Windows for Workgroups. If you are using an earlier
  1027. version on an IBM PS/2 or Micro Channel Architecture computer and your
  1028. RAMpage! board is configured for expanded and extended memory, you need to
  1029. upgrade your AST RAMTYPE.SYS driver after you set up Windows for Workgroups.
  1030. You will also need to remove the "rem" command from your CONFIG.SYS file so
  1031. that RAMTYPE.SYS will load properly.
  1032.  
  1033.  
  1034. Secretdisk II Disk-Cache Utility (FAST512.SYS)
  1035. ----------------------------------------------
  1036. This disk-cache utility will not work properly with SMARTDrive. It is
  1037. recommended that you use SMARTDrive, provided with Windows for Workgroups,
  1038. and remove all references to other disk-cache utilities from your
  1039. CONFIG.SYS and AUTOEXEC.BAT files. (If this utility is detected, Setup
  1040. removes it from your CONFIG.SYS file for you).
  1041.  
  1042.  
  1043. SideKick(R) Versions 1.0 and 2.0 and SideKick Plus
  1044. --------------------------------------------------
  1045. Miscellaneous problems may occur when you run SideKick as a TSR with Windows
  1046. for Workgroups. It is recommended that you use a PIF to run SideKick as
  1047. an MS-DOS--based application instead of loading it as a TSR.
  1048.  
  1049.  
  1050. SoftIce Debugger
  1051. ----------------
  1052. If SoftIce is loaded, Setup will fail when starting the Windows portion of
  1053. the program. It is recommended that you unload SoftIce before you set up
  1054. Windows for Workgroups.
  1055.  
  1056.  
  1057. SpeedFXR
  1058. --------
  1059. This program is incompatible with Windows for Workgroups when running as
  1060. a TSR. It tries to increase the speed of the floppy disk drives, but slows
  1061. them instead. To get the best results, use the -X option when loading
  1062. SpeedFXR. This will prevent SpeedFXR from remaining in memory and affecting
  1063. the speed of the floppy disk drives.
  1064.  
  1065.  
  1066. SUBST (MS-DOS)
  1067. --------------
  1068. Do not add or remove "substituted" drives while you are running Windows for
  1069. Workgroups. If you use the SUBST command before starting Windows for
  1070. Workgroups and do not change the state of the substituted drives from an
  1071. MS-DOS Prompt within Windows, Windows for Workgroups will work properly.
  1072.  
  1073.  
  1074. Super PC-Kwik Disk-Cache Utility (SUPERPCK.EXE)
  1075. -----------------------------------------------
  1076. Do not use this disk-cache utility simultaneously with SMARTDrive. There is
  1077. no reason to use two disk-cache utilities with Windows. It is recommended
  1078. that you use SMARTDrive, provided with Windows for Workgroups, instead.
  1079.  
  1080.  
  1081. Trantor T100 Host Adapter Driver (TSCSI.SYS)
  1082. --------------------------------------------
  1083. (For SCSI hard disk drives) - If you use the Trantor T100 driver
  1084. (TSCSI.SYS), you must use version 4.33d or higher. Earlier versions identify
  1085. the SCSI hard disk drive as a removable drive. This may cause problems when
  1086. you are using File Manager--for example, your system could fail while you 
  1087. format a drive, or you could get unexpected results when you delete files.
  1088. To get an updated driver, contact Trantor Systems, Ltd.
  1089.  
  1090.  
  1091. UMB PRO Version 1.07
  1092. --------------------
  1093. If you are running UMB PRO, you may experience problems running Windows for
  1094. Workgroups. In some cases, your system may fail. Make sure that you are
  1095. using only one memory manager with Windows for Workgroups. It is recommended
  1096. that you use HIMEM.SYS and EMM386.EXE, which are provided with Windows for 
  1097. Workgroups, to manage memory instead.
  1098.  
  1099.  
  1100. Vaccine
  1101. -------
  1102. If Vaccine is loaded, Setup fails when trying to modify your CONFIG.SYS and
  1103. AUTOEXEC.BAT files. You should unload Vaccine before you set up Windows for
  1104. Workgroups. You may also encounter problems, such as beeping, while
  1105. running Windows for Workgroups when Vaccine is loaded.
  1106.  
  1107.  
  1108. VIREX-PC Version 1.11
  1109. ---------------------
  1110. If VIREXPC.COM is loaded, Setup and Windows for Workgroups will fail
  1111. when KRNL386.EXE performs a write operation. Also, the first time Windows
  1112. for Workgroups is loaded, you may be returned to the MS-DOS prompt.
  1113.  
  1114.  
  1115. Virus Prevention Plus Version 5.0
  1116. ---------------------------------
  1117. If Virus Prevention Plus is loaded, you may not be able to set up Windows 
  1118. for Workgroups successfully. You may also encounter problems when you run
  1119. Windows for Workgroups. The Keyboard Lock program may cause Windows for 
  1120. Workgroups to fail.
  1121.  
  1122.  
  1123. Virusafe Version 4.0
  1124. --------------------
  1125. If this program is loaded as a TSR, Setup may fail while you are setting 
  1126. up Windows for Workgroups. It is recommended that you load Virusafe by using 
  1127. the /C- option. This option turns off the memory-change detection provided 
  1128. with Virusafe. Version 4.5 may correct this problem. For more information, 
  1129. see your Virusafe documentation.
  1130.  
  1131.  
  1132. XMAEM.SYS
  1133. ---------
  1134. XMAEM.SYS is a device that causes extended memory to act like XMA. This
  1135. utility is incompatible with Windows for Workgroups. It is recommended
  1136. that you remove all references to it from your CONFIG.SYS and AUTOEXEC.BAT
  1137. files before you set up or run Windows for Workgroups. XMAEM.SYS is
  1138. provided with IBM DOS version 4.0.
  1139.  
  1140.  
  1141. XMA2EMS.SYS
  1142. -----------
  1143. Windows for Workgroups will run correctly with XMA2EMS.SYS if it is loaded
  1144. on a computer that has an XMA board installed. Otherwise, this program is
  1145. incompatible with Windows for Workgroups. XMA2EMS.SYS is provided with IBM
  1146. DOS version 4.0.
  1147.